Is this a Ghost Controls TDS2?
Ghost Controls sells its Heavy Duty series as kits: the TSS1 for a single gate and the TDS2 for a pair, with the TDS2XP as the solar dual package. Each arm is a 12-volt linear actuator. On a TDS2 the primary arm has a 6-foot cable and the secondary arm a 32-foot cable that reaches across to the control box. Ghost’s TXX1 replacement arm is listed for both the TSS1 and the TDS2 primary.
The Ghost board is distinctive once the box is open: a blue block of four DIP switches, buttons marked LEARN XMTR, SET AUTOCLOSE TIME, 1st SET and 2nd SET, JOG OPEN and JOG CLOSE, red 10-amp fuses marked F1 and F2, and separate lights for power, battery condition, status, autoclose and transmitter. The on/off switch is on the bottom of the box.
None of these kits includes a battery. You will find either a 12 V deep-cycle marine battery or Ghost’s ABBT2 battery box with two 12 V batteries. That matters for diagnosis: on a Ghost gate the battery was picked by whoever installed it, not by the factory.
- Blue four-position DIP switch block on the control board
- Buttons: LEARN XMTR, SET AUTOCLOSE TIME, 1st SET / 2nd SET, JOG OPEN / JOG CLOSE
- Green POWER light (steady on transformer, blinking on solar) and yellow BATTERY CONDITION light
- Red 10 A fuses labeled F1, plus F2 on dual systems
- A separate marine deep-cycle battery or an ABBT2 battery box
- TDS2: two arms, one on a 6 ft cable and one on a 32 ft cable
- AXS1 three-button or AXP1 five-button Ghost remotes
Also labelled: TSS1, TDS2XP, TXX1
TDS2 at a glance
- Compliance
- System certified to UL 325, 7th Edition (per manual)
- System voltage
- 12 VDC
- Battery
- 12 VDC deep-cycle marine battery or ABBT2 battery box kit — not included
- Current
- 1–2 A typical when active; 20 mA standby
- Maximum gate opening
- TDS2: 24 ft total span; TSS1: 20 ft
- Weight vs. length
- Manual chart steps down from 900 lb on the shortest leaves to 300 lb at 20 ft
- Arm stroke
- 20 in maximum; 5.5 in minimum
- Speed and range
- 90° in approximately 15 seconds; 110° maximum opening range
- Operating temperature
- −5 °F to 160 °F (linear actuator)
- Arm cables (TDS2)
- Primary 6 ft; secondary 32 ft
- Fuses
- F1 10 A (first arm); F2 10 A (second arm, duals only)
- Solar
- Up to 30 W of solar charging
- Autoclose
- 6 seconds to 60 minutes
- Wire runs
- Up to 1,000 ft of 16 AWG stranded wire from transformer; up to 100 ft from solar panel
- Remotes
- AXS1 3-button included; AXP1 5-button optional
From Ghost Controls’s published documentation. Your unit’s label and manual take precedence.